HygroClip XD - Industrial Probe
다목적 HygroClip2 - 산업프로브
Features
• Measures relative humidity & temperature
• Calculates dew/frost point
• Power supply range: 5…16 VAC / 5…24 VDC
• Outputs: 0…1V / 0…5 V / 0…10 V / 0…20 mA / 4…20 mA
• Voltage outputs configurable via software
• Highest precision and reproducibility
• Excellent long-term stability <1 %RH / year
• Digital interface for calibration and measurement processing
Dimensions | ∅ 15 mm diameter & 100 mm, 250 mm, 400 mm, 550 mm oder 700 mm lenght. |
---|
Operating range electronics | -40..85 °C / 0…100 %rF |
---|
Range of application | -100…200 °C * / 0…100 %RH ; *Short-term peak load |
---|
Accuracy at 23 ±5 °C | ±0.8 %rh / ±0.2 K |
---|
Power supply / Power consumption | 5…16 VAC / 5…24 VDC |
---|
Current consumption | 7 mA (typical) @ 24 VDC, 0…10 V / 12 mA (typical) @ 5 VDC, 0…1 V |
---|
Long-term stability sensor | <1 %rh / year |
---|
Humidity sensor | ROTRONIC HYGROMER® IN-1 |
---|
Temperature sensor | PT100 1/3 DIN Class B |
---|
Probe protection | Brass, nickel-plated |
---|
Filter cartridge | No filter ex works |
---|
Maximum wind velocity | 3 m/s, without filter |
---|
Response time t 63 | <15 sec. |
---|
Psychrometric calculations | Dew and frost point |
---|
Probe adjustment by software | Single point, multipoint, dew point (%RH / °C), with service cable |
---|
Analog output signal (standard) | 0…1 V, 0…5 V, 0…10 V, 0(4)…20 mA |
---|
Digital output signal (standard) | UART or RS-485 |
---|
Max. probe cable length | 2 m / 5 m |
---|
Housing | PEEK |
---|
IP protection rating | IP65 |
---|
FDA / GAMP | FDA 21 CFR part 11 / GAMP5 |
---|
CE / EMC conform | 2007 / 108 / EG |
---|
Maintenance | Annual calibration recommended |
---|